英格瑪特/力士樂伺服驅動器故障維修:控制器是針對伺服電機特殊使用而的,也可能專為某些產品而制造,選用哪種控制信形式因設計師個人規劃理念而定,或選用控制器與驅動器一體規劃,絡式遠程控制,這些不是通用伺服電機評論的規模,但工作理論及工作形式是相同的。
DDS02.2-W驅動器F262輸出處故障修理:
F262 External Short at Status Outputs
狀態輸出處的外部短路
Description:說明:Status outputs are monitored for short circuits and thermal overload.監測狀態輸出是否存在短路和熱過載。
• If output current exceeds 350mA for about 1μs, then this is acknowledged as a short circuit and the pertinent channel is shut off.
•如果輸出電流超過350mA約1μs,則為確認為短路,并關閉相關通道。
The output remains off unti the error is cleared.
在清除錯誤之前,輸出保持關閉。
• With thermal overload, the error is set and the output(s) shut off. After
the driver has cooled off, the outputs are switched back on and so on.
•熱過載時,設置錯誤并關閉輸出驅動器已經冷卻,輸出重新打開,等等。
The error, however, remains until it is cleared. Thermal overload can
occur if several outputs are overloaded in excess of 80 mA.然而,該錯誤將一直存在,直到清除為止。熱過載可能如果多個輸出過載超過80mA。
Cause:原因:
1. Short circuited outputs (X2/6, X2/7, X2/8, X2/9, X2/10, X2/20,X2/21, X2/22)
短路輸出(X2/6、X2/7、X2/8、X2/9、X2/10、X2/20、X2/21,X2/22)
2. One or more outputs are overloaded.
一個或多個輸出過載。
Remedy:解決措施:
For 1. Eliminate short circuit or limit switching current (< 350 mA)
對于1。消除短路或限制開關電流(<350 mA)
For 2. Drop current, depending on output, to < 80 mA.
對于2。根據輸出,將電流降至<80 mA。
友情提示:請勿自行拆卸檢查或交給非專業人士,以免越修越壞,造成不必要的經濟損失!早一天聯系,少一天損失!上海仰光電子科技有限公司 因為專注,所以專業!
轉載請注明出處:上海仰光電子科技專業伺服驅動器維修,伺服電機維修
本文鏈接:http://m.ybap.cn/fuwu/Services_Show23126.htm
伺服驅動器維修 伺服電機維修 觸摸屏維修 變頻器維修
聯系方式:
電話:021-50157782
手機:13817011982 微信同號
郵箱:shygdzi@163.com
聯系人:張工
網址:http://m.ybap.cn
【 我們確保修好測試好給客戶!!!!】
上一篇:ABB變頻器ACS355系列故障報警2312如何解決故障/上海仰光
下一篇:沒有了